◉ Building Automation & Energy

BMS SYSTEM
IN KOLKATA

Integrated Building Management Systems (IBMS) for industrial plants, hospitals, hotels, IT parks and commercial complexes — unifying HVAC, energy, lighting, fire and security on a single supervisory dashboard. BACnet / Modbus / LonWorks expertise across Schneider, Johnson Controls, Siemens, Honeywell and Delta.

How A BMS / IBMS System Works

A Building Management System (BMS) collects sensor data from every plant and subsystem (HVAC chillers, AHUs, lighting, energy meters, water tanks) into field controllers connected over BACnet, Modbus or LonWorks. The supervisory server runs control sequences, energy optimisation and fault detection — pushing alarms to operator dashboards, mobile apps, and integrating fire alarm, CCTV and access control on a single pane of glass. Below is the typical IBMS topology Febino Digital deploys for industrial and commercial buildings across Kolkata and India.

BMS / IBMS topology — field subsystems connected via BACnet / Modbus to a supervisory server with operator dashboards and integrations ▸ FIELD SUBSYSTEMS HVAC PLANT Chiller · AHU · VAV · FCU SMART LIGHTING DALI · KNX · Occupancy kWh ENERGY METERS MFM · Sub-metering · ISO 50001 WATER & PLUMBING Pumps · Tanks · Leak Detect ▸ SUPERVISORY 12,840 POINTS · ENERGY −22% BMS / IBMS SERVER BACnet/IP · Modbus · LonWorks · Schneider · JCI · Siemens · Honeywell ▸ OPERATIONS + INTEGRATION OPERATOR DASHBOARD P&ID Graphics · Trends · KPIs CLOUD ANALYTICS EcoStruxure · Niagara · ML FIRE INTEGRATION FACP · Smoke Damper · AHU Trip CCTV + ACCESS Single Pane of Glass · IBMS FIG.04 · IBMS TOPOLOGY · BACnet/IP · ASHRAE 135 · 15-30% ENERGY SAVINGS
Field Bus: BACnet · Modbus · LonWorks
System Healthy: All controllers online
Energy Optimisation: Live sequences + analytics

What We Integrate

Febino Digital is a multi-brand BMS integrator with deep expertise in HVAC controls, energy metering, lighting automation and protocol gateways. We handle greenfield smart buildings, brownfield retrofits, and IBMS upgrades that integrate fire alarm, CCTV and access control on a single operator console.

01

HVAC Automation

Chiller plant optimisation, AHU / VAV / FCU control, sequencing, free-cooling, demand-based ventilation, condenser water reset.

02

Energy Metering

Multi-function meters on transformers, panels, DG sets and major loads. Real-time dashboards, ISO 50001 reporting, anomaly alerts.

03

Smart Lighting Control

DALI, KNX, 0-10V dimming, occupancy + daylight harvesting, scheduled scenes, façade lighting integration.

04

IBMS Integration

Fire alarm + CCTV + access control + PA + lift unified on one supervisory platform with cause-and-effect logic.

05

BACnet & Modbus Gateways

Protocol conversion between BACnet/IP, BACnet MS/TP, Modbus RTU/TCP, LonWorks, M-Bus and OPC for multi-vendor integration.

06

Cloud & Analytics

EcoStruxure Building Advisor, Niagara, OpenADR cloud — predictive maintenance, fault detection, energy benchmarking.

Our Implementation Process

SCHNEIDERJOHNSON CONTROLSSIEMENSHONEYWELLDELTATRANE

Industries We Serve

Pharma & Healthcare

Cleanroom HVAC, GxP-compliant BMS, OT precision control.

IT Parks & Offices

Multi-tenant BMS, energy billing, occupancy comfort.

Hotels & Hospitality

Guestroom controls, F&B HVAC, façade lighting.

Manufacturing Plants

Process HVAC, dust extraction, compressed air, energy.

Data Centres

CRAC / CRAH control, hot-aisle/cold-aisle, PUE optimisation.

Shopping Malls

Atrium HVAC, common-area lighting, energy metering.

Educational Campuses

Classroom CO₂ control, hostel water, scheduled lighting.

Airports & Metro

Public-area HVAC, IBMS with fire / CCTV integration.

Frequently Asked Questions

What is a BMS system and what does it control?

A Building Management System (BMS) is a centralised control platform that monitors and manages a building's mechanical, electrical and electromechanical systems — HVAC (chillers, AHUs, VAVs, FCUs), lighting, energy metering, water management, lifts, fire detection, public address and security access. It uses field controllers, sensors and actuators connected via BACnet, Modbus or LonWorks to a supervisory server with operator dashboards and analytics.

What is the difference between BMS, BAS and IBMS?

BMS (Building Management System) and BAS (Building Automation System) are largely interchangeable terms covering HVAC, lighting and energy automation. IBMS (Integrated Building Management System) goes further by integrating BMS with fire alarm, CCTV, access control, PA and lift systems on a unified dashboard — providing single-pane-of-glass operations for facility teams. Febino Digital designs and integrates all three tiers.

Which BMS brand is best for Indian commercial buildings?

The best BMS brand depends on building size, integration scope and lifecycle cost. Schneider EcoStruxure, Johnson Controls Metasys, Siemens Desigo and Honeywell EBI are the global leaders for large commercial and industrial deployments. Delta Controls and Trane are strong mid-segment options. Febino Digital is a multi-brand integrator and recommends the platform best suited to your project.

How much energy does a BMS save?

A well-designed BMS typically delivers 15–30% reduction in HVAC energy consumption through optimised chiller plant control, demand-based ventilation, occupancy-linked lighting and real-time energy metering with anomaly detection. Payback periods for retrofits range from 18 to 36 months depending on existing inefficiencies and tariff rates.

Do you provide BMS AMC and remote monitoring in Kolkata?

Yes. Febino Digital provides Annual Maintenance Contracts (AMC) for BMS systems in Kolkata and across India. Our offerings include preventive maintenance, controller and field-device service, sequence-of-operation tuning, energy reports, software upgrades, and optional 24×7 remote monitoring with alarm escalation.

Need a BMS System Quote?

Speak to a BMS / IBMS design engineer today. Free site survey for projects in Kolkata, Howrah, Durgapur, Asansol and across West Bengal.

📞 Call +91 98 7438 7438